In order to improve the security factor and control the access of individuals in companies and organizations, the use of access control system with Persian software is on the agenda of the collections.
The access control system is designed to allocate personnel access to different locations based on time and place constraints and pursues the following objectives:
- Maintain the security of the collection according to defined policies
- Identify personnel and control their time and place of traffic
- Ability to track and follow events in a specific time period
- Controlling people's access by issuing licenses to doors, gates using fingerprints, card and code.
- Using comprehensive access control software to store all system information, including authorized, unauthorized, external commands and… along with the preparation of filtered reports and integrated information management.
- using electric lock and magnetic lock (Selection based on the type of door) to provide the required level of security based on the type of entrance, use and location.
- Intelligent inputs using Magnet Sensor , PIR and module alarm
– قابلیت ترکیب access control - Ability to combine access control system with video door phone and remote control to issue a pass at the same time.
Controller (Access Control Unit)
2- Types of readers (card reader, card & pin reader and fingerprint access control)
3- types electric lock and magnetic lcok
4- Types of push buttons (steel, no touch and touch)
5- Magnetic sensors (wireless and wired) and motion detection sensors (PIR)
6- Alarm modules and Remote (Independently or Wiegand protocol)
All components of the access control system are connected to the controller with Persian software and behave according to the controller's planning by the comprehensive Golden key access control software.
Therefore, localization of this unit (Access Control Unit) in terms of hardware and software, increases the power of implementing an integrated access control system.
- Has 1000 user memory (card, code, fingerprint and remote control) can be increased up to 10000
- Has 2000 record recording memory (allowed access, door opening and…) can be increased up to 16200
- Has a comprehensive Persian access control software under Windows in two general and advanced versions
- Output for all types of electric locks, magnetic locks and automatic doors (NO, NC)
- Directional alarm relay output external alarm (NO command) and NO alarm caller
- Has inputs Magnet Sensor NC, pushbutton and PIR as NO
- Has alarm module inputs and remote control in the form of Weigand26
- Support for all learning remote controls with a frequency of 433Mhz, 315Mhz
- Kidney support Weigand 26 card readers Frequency 125Khz - 13.56Mhz
- Completely secure, if opened card reader It is not possible to penetrate from the installation site
- Ability to set the command relay time from 1 to 250 seconds and alarm relay time from 1 to 250 seconds
- Ability to communicate with the computer through RS485 converter Two wires and LAN (TCP / IP)
- Ability to register a planning card for off-line use (to register and delete the card)
- Ability to register a lock card, free for off-line use (change the system mode in special circumstances)
- Has three modes of operation normal, safe, free (By Pass for use for a variety of uses)
- Fully user-friendly and accessible User Friendly environment
- In 64-bit and 86-bit versions with SQLite database
- Ability to define the user and restrict access to settings
- Online monitoring with filtering capability (door type, access type and etc.)
- Grouping doors to facilitate access for users
- Ability to create a schedule to receive events on a daily basis
- Ability to work with software in Off-Line mode and hardware updates
- Ability to define a desktop card reader for ease of card registration by the operator
- Ability to increase unlimited controller and communication via LAN (TCP / IP), RS485
- Has the ability not to delete access records without archiving and preserving information