Description
Smart Parking System
The smart parking system S is a new way of security and traffic for entering the parking lot.
In the not so distant past, we definitely had a lot of time and suffering to enter the parking lot. It was difficult to get out of the car in the heat and cold and to open the parking lot door manually.
Today, with the advancement of technology, all these operations are achieved in a fraction of time and in complete ease.
Using pneumatic and electrical jacks, bar and column barriers, electric shutters and… (depending on the type of passageway) and combining it with a remote control system, the door opens and closes automatically.
For a long time, the described operations were performed in modern and luxury buildings, but today you rarely see a building that does not have this system.
But what are the problems with using a remote control system?
- With the disappearance of one RemoteIn order to maintain the security of that set, all remotes must be cleared and re-registered on the receiver.
- Ability to copy remotes despite Bluetooth remotes in the market by non-experts
- And finally, the relatively high price of remotes compared to car labels or RF cards
پیشنهاد ما استفاده از سیستم هوشمند پارکینگ S
What are the benefits of using the intelligent S parking system?
- Restricting access and defining the time limit for authorized acess
- Ability to control access with software and provide reports at the time of the event
- The best alternative to remote control in terms of increased security and reduced costs
- Ability to register and delete the user with the software and create a backup file of users
- Ability to disable access at the time of the event using the software
- Send the command with the software to the barrier or jack command circuit, for emergency brittleness
- Ability to temporarily disable the access of one or more specific numbers (people who have not paid the building charge)
The components of the intelligent S parking system are:
– controller (Select based on user type)
- Readers Long range UHF or Short range RF
– پایه های فلزی L مناسب جهت ریدرهای UHF و یا RF
- Flexi tube and cable suitable for data transfer from readers to controller
- Types of UHF tags (simple and shredded) and UHF cards
روش کار سیستم پارکینگ هوشمند
در سیستم پارکینگ هوشمند وظیفه اصلی controller, Is to determine whether the brittle is allowed or not and send the appropriate signal to the door control circuit.
Each label (UHF label) has the ability to register a unique number at the time of coding, so after exposure Reader The label / card number is read and sent to the controller via the Weigand26 protocol.
If the label number is confirmed by the controller, a pass signal is issued for access to the control circuit of the door jack or barrier.
Depending on the type of user and customer request, UHF long-range readers with a range of 4 to 12 meters (reading distance varies depending on the type of reader and brand) or RF short-range readers with a range of 10 to 120 cm can be used.
UHF labels are available in both shredded and plain models.
In the crushed type, there is no possibility of any abuse because by removing it from the installation place (sticking it on the car window), the chipset and antenna used in it will be destroyed.
Temporary UHF cards can also be used for guest cars or rental cars that travel for a limited time.
نکته در خصوص اجزاء سیستم پارکینگ هوشمند
در سیستم پارکینگ هوشمند همانطور که گفته شد نقش ریدر ها فقط خواندن شماره لیبل/ کارت و ارسال آنها به کنترلر می باشد.
Therefore, the type of reader and the quality of its construction will affect the speed and accuracy of reading the label number.
A very important point in the implementation of smart parking projects is the location of the readers.
Due to the fact that UHF readers operate linearly, so its location in the passageway should be such that when the car is completely stopped, the label on the glass in line of sight UHF reader Otherwise the system will encounter an error.
In some buildings, the distance between the input passageway and the output is very large, so due to the limited distance between the reader and the controller, in such cases, two single-channel controls are used instead of a two-channel controller.